OSHA portable toilet rules for construction, in plain words.

The rule is 29 CFR 1926.51(c). It sets a minimum count by crew size, requires the units be kept sanitary, and requires handwashing. Florida has no state OSHA plan, so federal OSHA covers private construction sites.

The count: 1926.51(c)(1), Table D-1

Workers on siteMinimum toilets (OSHA 1926.51 Table D-1)At weekly service (ANSI Z4.3)
Up to 201 toilet1 per 10 workers
20 to 1991 seat + 1 urinal per 401 per 10 workers
200 or more1 per 501 per 10 workers

Sanitary condition

Toilets must be kept clean and in working order. OSHA's May 17 2006 interpretation letter says an unsanitary toilet does not count toward the required number. In practice: a unit pumped once a week for 20 workers in a Florida summer is not compliant by midweek. Plan service by use, not by the calendar.

Handwashing: 1926.51(f)

Employers must provide washing facilities with soap and single-use towels or dryers. A handwash station next to the units is the normal way to meet this.

Mobile crews: 1926.51(c)(4)

Mobile crews with transportation readily available to nearby toilet facilities are exempt from the count. A road crew with a truck and a gas station nearby qualifies. A 3-month vertical build does not.

Florida Building Code

FBC Plumbing 311.1 requires toilet facilities for construction workers and that they be kept sanitary; non-sewered units follow ANSI Z4.3. There is no statewide rule that a unit must be on site at a given inspection. Check your jurisdiction.

What a citation looks like

"Anyone ever report a jobsite for a disgusting porta potty? Superintendent, foreman and porta potty company all were reprimanded."r/Construction, 2025

Hurricanes

Fort Lauderdale's jobsite checklist says remove or tie down portable restrooms. Manatee County and Fort Myers Beach set jobsite preparation at 48 hours before a hurricane warning's expected landfall. United Site Services' guidance: latch the door, face the unit toward a barrier, strap it, sandbag it, and never upright a tipped unit yourself.

Sources: 29 CFR 1926.51; OSHA standard interpretation 2006-05-17; FBC Plumbing 311.1 (2023); ANSI/PSAI Z4.3; county hurricane guides. This is a summary, not legal advice.